hayward blue essence troubleshooting

*. Or to a light switch and then to a breaker, that would be more of a standard installation. Do you have any idea what I need to do to remedy the problem. I have a S-210 Hayward pool pump and it started spitting sand so I bought a Folding Umbrella Lateral Holder AssY when I dumped the sand out I think 2 of them were broken for a couple of months it seems sand has been dumping in the pool thats why I bought the lateral. Not the power leads, but other connecting wires from the terminal board to the switch, to the cap? If thats not the issue, is the pump sized correctly for the filter, and not under/over sized? For slide valves (aka push-pull valves), an o-ring on the bottom plunger disk has gone missing or is worn, torn or badly deteriorated. We are out of ideas and no one can solve this. Do you have a video clip to show how to replace it? Hi Scott, if the cracked case seal has any possibility of letting water in, maybe you can silicone it to seal it up. Grids not aligned properly, thus not pushed fully up into manifold It worked great for the season. Hi Shaun, if its not an air leak (from a loose pipe going into the pump, or loose pump lid, or low water level, or stuck skimmer weir), it then most likely is a clogged pump impeller. I check electrical from the panel breaker, to the timer to the circuit breakser to the switch to the outlet, through the wire to the pump and power is getting to the pump. Hola tengo una caldera Hayward H400 PED2 durante el intento de encendido no enciende m caldera despus de 5 intentos me pone lF en la pantalla. Its never happened before. Old pump ran on 120v and ran just fine till we broke it. If regular loudness, its likely an air leak. The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. "address": "",
I am a novice with in ground pools, but is the pool motor supposed to run continuously? Motor will hum for a few seconds and eventually trip the breaker. Automatic restart is 2 minutes after the error condition is corrected and the limit string closes. Click Here to View Replacement Aquarite Parts The latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing the , . What do you suggest? The mechanical shaft seal sits behind the impeller, and prevent water from leaking out along the motor shaft. I would inspect it for corrosion, wire tightness, water damage or insect damage. I removed the back of the pump and the yellow wire has a small black burn hole in it. Set the test meter to Ohms, of 1K or higher. Does a Hayward super pump wired on 230v have to have a controller?.. Is it problem of filter ? I open the plastic door, fill with water and sometimes need to do this several times in order for it to keep going. Please advise. Just opened my in ground pool went to turn the pump on and nothing. We recently noticed the plug and cord are getting hot and the rubber is beginning to melt. The trick is the little plug on the electrical panel MUST be moved to either 230 (up one) or to 115 (down). 4 New pump 2 years old. Essentially, its probably something loose/broken, or a bad capacitor, which is like the battery to help it get up to high speed. Heyward 1.5 hp runs for a while and then top of pump pops off when I reset it works for a while and then pops again could It be pressure building up due to dirty filter? Hayward recommends 1.5 PVC pipe, and more than one line, (i.e. Thanks for your insight. Air leaks are another source of priming issues. It wont stop leaking. Drain plugs, pump lid, pipe coming into pump, skimmer or main drain valves, low water level, stuck skimmer weir, or the dreaded underground cracks in pipe (rare problem). Where can I get a new yellow wire to connect the motor to the switch and see if this solves my issue? outlet still on. If you see an increase in pump pressure, ensure that there is no blockage preventing the flow. If the motor is fried, you can either replace the motor and shaft seal or spend more, and replace the entire pump (although the motor is the only thing you would really need). Spray off well, and soak in a 5-gal bucket, the entire Flex Tube Nest, for a number of hours, hose off again, soak for another few hours, hose off thoroughly, dunk in the pool a few times, then replace in the filter tank. (This pump is on a regular 20 amp circuit breaker, not a GFCI.). "description": "Hayward Pool Heater Troubleshooting Guide - how to step by step approach to determining if the water supply, gas supply, electrical supply or a component of the heater is causing the issue. Use a flashlight, and you should see gears moving thru the small view hole. If the shaft is free turning, but the pump does not turn on, check power connections. We replaced all the seals in the pump and ran a completely new line even from the pump directly into the pool and it will not hold prime. After installing the new pump, priming it, it started running as normal, after a short time the new pump shut down and was very hot. "wordCount": "1194",
Does it only do this when vacuuming, but otherwise runs fine? If you had a multiport valve, you could put it on recirculate and verify, but since perflex have no such valve, the only other test would be to actually plumb around the filter, by installing a bypass valve and line, or just temporarily routing plumbing around the filter, to bypass the filter completely. Just replaced the upper lid on my Vari-flow and spider gasket, also changed out 300 lbs filter sand. The other rectifier is rated as 18-33 VDC. "@context": "https://schema.org/",
The regular tristar is only $100 cheaper now, so Id go for the Tristar VS. On/off on/off. Might wait to see if Hayward can give you an answer and probably want to contact the vendor who sold you the pump, which Hayward may require anyway? replace the entire pump with exact replacement. The display shows nothing as if it is not getting power. Motor is connected to 220 volts and each phase consume 3.8 amps. last year, I replaced the Sand & O ring on the filter, and I resealed the O ring on both the filter & Pump with O ring lube. I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. The second thing that can cause such a problem is if the pump is starved for water, cavitating, because it is too large (hp) for the piping system, or because incoming valves are closed, or pipes are plugged, or clogged. Mine hums and then trips the breaker. Any idea? Anyway I decided to run it and it appears that the pump runs full power with the returns pushing out with lots of force for about 5 minutes and then it weakens. Currently it is at pool level. Calling the pool builder for warranty info, too. Any thoughts? If the impeller wont spin, this is likely the problem. Work through the chart below if your heater displays the following error codes. What am I missing? If the pump runs without water for very long it will burn up the shaft seal, and if run for hours and days, can literally melt the pump, sometimes even catch fire (rarely), even with a small amount of water in it. Hi, thats strange! I replaced the rod, and now my lid will not go down, the rod is the exact same as the other. Usually get 3-4x that long. So I installed a brand new Hayward W3SP2610X15 Super Pump Pool Pump, 1.5 HP last season Summer 2019 and used the electric cord from the old one which was showing its age. Everything seems to be set up correctly on the filter and motor. A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs. After I installed the ne motor, I pugged it in, started the pump and the breaker tripped. Came out tonight and flipped the switch and pump started. If they are tight, pull out the cartridge and drain the tank whatever it is may be laying in the bottom of the tank. "@type": "ImageObject",
Maintenance. When he went to turn the pool back on it made a slight humming noise like it was trying to come back on but it wouldnt turn on. You might be surprised by how many people neglect to check this area. Sorry for the bad news. Guess it is time for a new drive. I have the intermatic digital two speed timer. The error code will be cleared upon a valid data exchange between boards, If the limit string opens the heater shuts down and goes into lockout. Gas pressure is ok. Any ideas? 2 No loss of water level in the pool Any suggestions? American Freight San Antonio, Is this a 2-speed pump, or variable speed pump? if the motor is generating too much heat, this temp sensor will trip and shut off the pump. After just a few minutes the flow slows down to almost nothing. Hi, we just installed a new AquaRite unit and it has been running for 48 hrs The salt level is 3100 ppm (pool store also confirmed and tested the water, no issues detected with the water). This blog is an in-depth look at the Aqua Rite and Aqua Rite XL diagnostics manual created by Hayward. I am thinking it must be the age of the pump. However this is not correct operation. I checked the breakers, plumbing, control panel, plumbingjust need to know if I shud prepare myself to buy a replacement. We have a hayward pump and heater. What are some items I should check assy A for on the bench so I can possibly repair it? "width": "611",
Fourth, check the motor shaft to be sure that it spins easily by hand, fifth, you can check the capacitor (for capacitance), if the motor still isnt starting. Loose connections or insect infestation on contacts, or loose breaker etc, could also cause a different type of start/stop problem, very rapid. Heater wont ignite when water temp is above 80 degrees. Pat. The fact that it runs all day fine with a HD power cord attached and plugged in, makes me think its not a motor issue. Hi COnnie, great question! Hi Mark, hard to say if it does not display any error code, the caution symbol on a Hayward Heater is usually accompanied by an error code, LO being the most common, for low water flow. Replumb your flow switch if it does not meet the distance requirements. Or very high mineral content (very hard water), or oily substances. Suggestions ? If youre correct that theres a problem with the internal bypass, what should I do? I had an old hayward 1.5 hp power flo matrix 2 speed pump. Could it have shut it self off from overheating? Upon restart, pump sounds horrible, like pumping rocks. Also check that the clips and o-rings on the SS bump shaft are all in place. Loose wiring, or broken wires, or wires nearly touching each other, and arcing. Hi Dave..your honest opinion please..new 14000gal gunite pool with hayward sp3400vsp pump September 2014,ran a month winterized and ran fine for 3 years, when company came to open up the pool in 2017,pump stuck,installed new 3400@ $1200. I have a 2 HP Hayward two speed pump that is on its second season. Dont know if I need a new pump or what. Holes in grids, or stitching coming apart If very clogged, you can usually tell, because debris will float out and you can grab some of it with your fingertips or with pliers. If valve is open when it should be closed the heater will shut down and go into lockout. ) and you should be able to feel debris lodged in the impeller with your fingertips. Please note: The majority of our literature and brochures are in English only. I have to say Ive never touched it before during almost 6-years of normal operation. Possibly a bad breaker, they do wear out after 20 yrs or so. Problem is now the pool will not clean up (algae) and the pump is slow to prime. I have taken it apart and put it back together probably 5-6 times looking for internal issues. When I turn on my clock and put my ear close to the clock I hear the clock sound like its on but my Hayward filter does not turn on and makes no noise. Put everything back in place, turned pool on. There should be no continuity. Or you can try a filter cleaner first, to remove oils and scale that may be clogging the filter. I have a Hayward pump with DE filter. If I prime the pump and turn it on it runs fine but when I turn it off and let it set for a few minutes you can hear it cheering then the water in the pump evacuates and there appears to be some water coming from the bottom of the pump. However, we are not able to remove the pump. Be sure that all pool valves are open and any wall plugs are removed before turning on pump. If still stumped, use a power meter to find the problem lies where the power dies, and trace power from the breaker to the timer or outlet, to the motor. If the capacitor doesnt fix it, you may need a new motor, or pump, barring other issues that can be seen readily. search, pool & drain cover safety Perhaps you can replace it with a 20 amp breaker, of the same manufacturer, and youd be all set, or move some of the other devices to draw power from a different breaker. "dateModified": "2/24/2015",
I dropped $200 on a new pump and it is doing the same thing. But most plastic impellers are closed nowadays, with non-visible vanes. So My pool pump is two speed and I have it set to run for 3 hours in low speed and 5 in high. I didnt plug the line and got a lot of water on the pump motor. Additionally, ensure all o-rings, valves, and gaskets are lubricated and situated in the right positions.